Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Med Phys ; 50(3): 1680-1698, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36583665

RESUMO

PURPOSE: In recent years, the FLASH effect, in which ultrahigh dose rate (UHDR) radiotherapy (RT) can significantly reduce toxicity to normal tissue while maintaining antitumor efficacy, has been verified in many studies and even applied in human clinical cases. This work evaluates whether a room-temperature radio-frequency (RF) linear accelerator (linac) system can produce UHDR high-energy X-rays exceeding a dose rate of 40 Gy/s at a clinical source-surface distance (SSD), exploring the possibility of a compact and economical clinical FLASH RT machine suitable for most hospital treatmentrooms. METHODS: A 1.65 m long S-band backward-traveling-wave (BTW) electron linac was developed to generate high-current electron beams, supplied by a commercial klystron-based power source. A tungsten-copper electron-to-photon conversion target for UHDR X-rays was designed and optimized with Monte Carlo (MC) simulations using Geant4 and thermal finite element analysis (FEA) simulations using ANSYS. EBT3 and EBT-XD radiochromic films, which were calibrated with a clinical machine Varian VitalBeam, were used for absolute dose measurements. A PTW ionization chamber detector was used to measure the relative total dose and a plane-parallel ionization chamber detector was used to measure the relative normalized dose of each pulse. RESULTS: The BTW linac generated 300-mA-pulse-current 11 MeV electron beams with 29 kW mean beam power, and the conversion target could sustain this high beam power within a maximum irradiation duration of 0.75 s. The mean energy of the produced X-rays was 1.66 MeV in the MC simulation. The measured flat-filter-free (FFF) maximum mean dose rate of the room-temperature linac exceeded 80 Gy/s at an SSD of 50 cm and 45 Gy/s at an SSD of 67.9 cm, both at a 2.1 cm depth of the water phantom. The FFF radiation fields at 50 cm and 67.9 cm SSD at a 2.1 cm depth of the water phantom showed Gaussian-like distributions with 14.3 and 20 cm full-width at half-maximum (FWHM) values, respectively. CONCLUSION: This work demonstrated the feasibility of UHDR X-rays produced by a room-temperature RF linac, and explored the further optimization of system stability. It shows that a simple and compact UHDR X-ray solution can be facilitated for both FLASH-RT scientific research and clinical applications.


Assuntos
Aceleradores de Partículas , Fótons , Humanos , Raios X , Radiografia , Água , Radiometria , Dosagem Radioterapêutica , Método de Monte Carlo
2.
Environ Sci Technol ; 55(14): 10046-10055, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34197097

RESUMO

China has been promoting one of the world's largest campaigns for clean heating renovation since 2017. Here, we present an integrated cost-benefit analysis in a major prefecture-level city by combining a large-scale household energy survey and PM2.5 exposure measurement, high-resolution chemical transport simulation, and health impact assessment. We find that the completed renovation decreases the share of solid fuels in the heating energy mix from 96 to 6% and achieves a concomitant reduction of cooking solid-fuel use by 70%. The completed renovation decreases the ambient PM2.5 concentration in Linfen by 0.5-5 µg m-3 (2.4 µg m-3 on average) and decreases the integrated PM2.5 exposure by 4.2 (3.5-5.0) µg m-3. The renovation is estimated to avoid 162 (125-225) and 328 (254-457) premature deaths annually based on two health impact assessment methods. The ratios of monetized health benefits to cost are 1.51 (0.73-2.59) and 3.06 (1.49-5.23) based on the above two methods. The benefit-to-cost ratio is projected to remain high if the renovation is further expanded. More polluted and less wealthy households enjoy larger health benefits but also experience a higher expense increase, suggesting that a more carefully designed subsidy policy is needed to protect low-income households.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluição do Ar , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Poluição do Ar/prevenção & controle , Poluição do Ar em Ambientes Fechados/análise , China , Culinária , Análise Custo-Benefício , Calefação , Humanos , Material Particulado/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA